Safety module NC86

Functional description

Safety control to be used as interlocking device for movable guards designed to protect people and machines from dangerous situations. The NC86 can control the state of two contacts (reed sensors, emergency stop button, mechanical safety switches).

Application fields

  • Control of correct closing of dangerous gates or guards
  • In conjunction with magnetic sensors it is the ideal solution for environments with high hygiene requirements, reduced installation spaces, poor door approach accuracy, environments with dust or humidity.
  • Emergency stop button control.
  • Elevator leveling and re-leveling safety circuits.
  • Elevator uncontrolled movement detection circuits.

Main features

  • Safety category 4, PL e according to EN13849-1
  • 24V AC/DC power supply
  • 2 Inputs for NO sensors
  • 2 Safety outputs
  • 1 Transistor auxiliary output
  • Automatic or manual start
  • Certified also according EN 81-20 and EN 81-50 as safety circuit for elevators